Version History SafAlert Notifier (tm) ComTekk Engineering, LLC www.comtekk.com Ver.3.17 25-May-2012 (XP/Vista/7) ================================ 1. Updated gateways.csv (mobile carriers, US Cellular, et al) 2. Fixed alert list editor bug - when deleting tone or responder, name below gets cleared 3. Updated libraries: Audio/DSP 5.1, email 7.1, GUI 10.1b 4. Added emailing status indicator on Alert List form 5. New email library should improve error recovery 6. Forms now sized dynamically to accommodate Windows Magnifier Ver.3.16 15-Mar-2012 (XP/Vista/7) ================================ 1. Fixed SSL proxy path, causing error sending mail Ver.3.15 2-Mar-2012 (XP/Vista/7) ================================ 1. Limited SMTP to (2) connect attempts or 30 seconds timeout, was taking up to 3 minutes if bad server info used 2. Added error check for illegal filename symbols [\*/?:"<>|] in Unit ID Ver.3.14 2-28-2012 (XP/Vista/7) ================================ 1. Fixed "unable to load gateways.csv" error when launching on Windows bootup 2. Reduced height of Alert List form to < 600 pixels so it will fit on netbook screens Ver.3.13 1-24-2012 pm (XP/Vista/7) ================================ 1. Fixed bug causing some responders to be skipped when sending MMS (emails with audio) on stacked pages Ver.3.12 1-24-2012 (XP/Vista/7) ================================ 1. Resolved program freeze on SMTP connect failure. Ver.3.11 [beta] 1-20-2012 (XP/Vista/7) ================================ 1. Resolved issue preventing text messages from sending in certain circumstances 2. Message counter more accurate, now includes BCC recipients 3. Carrier drop-down in Alert List will now index to current selection for a given row. 4. When new Tone-out or Responder is added, list will now advance to bottom as needed. 5. Fixed CC email getting duplicate messages 6. Added Audio Recording disabled status indicator on Alert List Ver.3.1 [beta], 1-13-2012 (XP/Vista/7) ================================ 1. Fixed error reading gateways.csv file, now reads only once on program launch 2. Added clock and VU meter to main screen 3. Added error checking on carrier selection for email address Ver.3.02, 12-29-2011 (XP/Vista/7) ================================ 1. Updated MIME content type for audio attachment to resolve issue with new email library Ver.3.01, 12-20-2011 (XP/Vista/7) ================================ 1. Fixed issue with Email List not initializing on new install 2. Improved Alert List error checking 3. Fixed bug preventing new Alert List entry if no rows existing Ver.3.0, 12-15-2011 (XP/Vista/7) ================================ 1. Program data files now stored in common app data folder (same for all Windows users). C:\ProgramData [Win7/Vista]; C:\Documents and Settings\All Users\Application Data [XP] 2. Added option to extend recording time when additional tones received after recording started 3. Email list now more intuitive, easier to enter cell phone addresses. Old list auto-imported 4. SMTP and event logs now saved to Logs folder (smtp.log, events.log) 5. Option to send SMS / text-only emails immediately after tones. MMS sent after recording completes. 6. Re-arranged some tabs and panels in Settings window, to be more intuitive and make room for new features. 7. Added Unit ID argument and run on every page options to Run File 8. Fixed restore All CC email settings 9. Added check of SMTP connection status before closing 10. Added error checks and thread management to help prevent lockup when trying to send mail without Internet connection, or incorrectly formatted email address. 11. Added SafAlert SMTP to Mail Auto-Configure 12. Audio now unMuted during playback 13. Added log file viewer/player, external program no longer needed 14. Last selected settings tab saved on exit 15. Added Pager-Test tone set to temporarily disable decoder during a pager test 16. Preferences now saved when Settings window is closed 17. Added X10 PLC (Power Line Carrier) fire station alerting (FSA) features 18. Added password options for Alert List and FSA settings 19. Annual licensing implemented 20. Number of active members now displayed in Stats 21. Help buttons added to forms 22. Added SSL support for outgoing email (SMTP) Ver.2.32, 17-Mar-11 (XP/Vista/7) ================== 1. Corrected double recording in VAD mode Ver.2.31, 13-Mar-11 (XP/Vista/7) ================== 1. Added seconds (time) to audio filename. 2. Corrected delay after tones recorder timing 3. Increased minimums delay for VAD mode 4. Fixed recording of new alert while previous alert still active Ver.2.3, 10-Mar-11 (XP/Vista/7) ================== 1. Platform independent audio codec (LAME mp3) to enable recording on newer versions of Windows 2. Removed WAV file recording option. Selection for 16kbps or 48kbps (AT&T) MP3 bitrates 3. Added program statistics to Diagnostics tab 4. Email list may now be edited like an Excel spreadsheet (click twice instead of dbl-click) 5. Fixed bug in delayed recording modes 6. Added voice activity detection for recording control 7. User may now select 3 different modes for recording - immediate, delayed or voice activated 8. Decoder improved to capture stacked pages without gap 9. Activity panel width increased to display longer text entries 10. Added 30-sec. wait if mail thread busy (happens if attempt is made to mail new alert message when mail from previous alert is still being transmitted). 11. Increased minimum number of tones/emails allowed to 10 by default 12. Error checking for mail addresses added 13. Restored functionality of "All CC" email address. Ver.2.21*, 30-Oct-10 (WinXP) ================== 1. *New activation key required for this version - must provide fingerprint code to ComTekk 2. Fixed code to prevent repeated listing of Unit IDs in MMS message 3. Increased stack delay to 5 sec. min. before sending emails, and checking for mail thread busy 4. Added user setting for Delayed Recording control 5. changed MP3 format to 48kbps to accommodate AT&T MMS 6. Email sending method changed to utilize Bcc, reducing time to send. 7. Units paged will remain on activity list until next alert 8. Win7/Vista audio controls incorporated 9. Added notch filter to decoder settings - to filter out a single frequency, i.e. tone remote 10. Main & alert window positions saved on exit 11. Additional diagnostics settings saved on exit 12. Changed method of stop recording to prevent audio device errors 13. Added clipping indicator to Audio Source VU meter 14. Added option to disable program exit confirmation dialog 15. On launch, replay button enabled for last recording. 16. Recording can be set in 5-sec increments, min. 25 seconds 17. Mute state restored after alert timeout 18. Audio file name changed to that of first unit alerted in a sequence Ver.2.15, 10-Aug-10 (Win7/Vista) ==================== 1. Removed audio components with Vista/7 compatibility issues that were causing errors on some machines. 2. On launch, replay button enabled for last recording. 3. Input device selector added for Vista/7 4. Some minor GUI/convenience enhancements Ver.2.14, 8-Aug-10 (Win7/Vista) ------------------------------------ 1. MP3 audio codec not working in Windows7, was disabled by Microsoft. WAV recording available, switched to GSM 6.10 encoding. 2. Changed default SMTP port to 587 for GMX mail, since many ISPs are blocking port 25. Ver.2.13, 3-Aug-10 (WinXP) ================= 1. Single-tone duration setting wasn't being saved on exit, fixed. 2. Email list with only one entry wouldn't be scanned & sent. Fixed. ====================== Ver.2.12 Initial Release, 1-Aug-2010 ======================